- SI900 Series |
Ideal applications : |
- SI8600 Series |
Centralized server center, mainframe, network control center, computing center |
- SI8900 Series |
Features : |
UPS for Banking Solution |
1. High frequency and dual conversion on-line technology |
Switching Power Supply |
2. Wide input voltage range |
DC Power Supply |
3. Digital control technology |
AC Power Source |
4. N+1 redundancy parallel function (6~10KVA) |
Variable Transformer |
5. Advanced PFC Technology |
Energy Saving |
6. True sine wave output with less than 3% THD |
Other |
7. Self-diagnosis at UPS startup |
|
8. Advanced battery management (ABM) |
|
9. Cold start feature (DC power on) |
|
10. Automatically charing batteries in UPS off mode |
|
11. lightning and Surge protections (Surge energy rating 1050 Joules) |
|
12. Short circuit and overload protections |
|
13. Fan speed automatically changes as load varies |
|
14. Optional external battery pack |
|
15. EMI/RFI noise filter |
|
16. RS232 |
|
17. (Shutdown & Restart schedule) |
Technical Specifications : |
Model |
SI901 |
SI902 |
SI903 |
SI906 |
SI910 |
VA Rating/Real Power Rating |
1KVA/700W |
2KVA/1400W |
3KVA/2100W |
6KVA/4200W |
10KVA/7000W |
Input |
Voltage Range |
Half-Load 120-300VAC, Full-Load 165V-300VAC |
176~276VAC |
Frequency Range |
45.5Hz~54.5Hz |
Power Factor |
>0.95 |
Output |
Voltage |
220/230/240+-1% |
Frequency |
50/60Hz+-0.5 |
Distortion |
<3%(linear Load); <5%(Non-linear Load) |
Waveform |
True Sine Wave |
Efficiency |
>85% |
Overload Capability |
110%~150%: Switch to Bypass after 1 Min; >150%: Shutdown after 200ms |
110%~150%: 10Min; >150%: 1Min |
Crest Factor |
3:1 |
Short Circuit |
UPS turn off output and Alarm |
Battery |
Model |
12V sealed lead acid mainternance free |
Voltage |
36VDC |
96VDC |
240VDC |
Configuration |
3x12V/7AH |
8x12V/7AH |
20x12V/7AH |
20x12V/9AH |
Recharge Time |
90% capacity after 8 hrs charging |
Charge Current |
Standard Model:1A; Long time Model:7.5A |
Standard Model:1A; Long time Model:5A |
Others |
Communication Interface |
RS232; SNMP(Optional) |
LCD and LED |
Utility, Inverter, Bypass, Battery, Load, Battery Mode, Frequency, UPS Fault indicator |
Audible Alarm-Battery Discharge |
Utility Failure, Beep/4s; Battery Low, Beep/1s |
UPS Abnormal |
Continuous Beep and Red LED on |
Noise Level |
<55 dB |
Ambient Temperature |
0~40 C |
Humidity |
10%~90% |
Dimension (mm) WxHxD |
145x215x415 |
190x330x470 |
260x730x560 |
Net weight (kg) |
6.5(H), 12.3(S) |
13.2(H), 28(S) |
40.5(H), 86.3(S) |
Packing Dimension WxHxD |
236x316x492 |
337x482x602 |
355x815x650 |
Gross weight (kg) |
7.6(H), 13.3(S) |
14.5(H), 29.3(S) |
42.8(H), 93.6(S) |
|
copyright © 2011, Silic Stable Service Co.,ltd. All